Wednesday, June 12, 2019
Lab Report - Precision and Accuracy Example | Topics and Well Written Essays - 1000 words
- Precision and Accuracy - Lab Report ExampleThe determiner of verity is the percentage error, which is valued at 0.06%. Some of these include the lack of experience and poor technique, which actually both go together for when there is lack of experience, the speedy result would be poor technique. Poor technique may be attributed to the parallax error, or the failure to put the eye at a level which is aline properly to the quite a little mark of the pipette. This means that if one is looking up the pipette, one can see a meniscus placed too tall when it appears to conform with the volume mark. In the same way, if one is looking down at the pipette, the meniscus will then be too low when it appears to align with the volume mark. In fact, aside from errors in the placement of the eye with reference to the volume mark, lack of experience and poor technique also translate as the failure of properly aligning the meniscus with the volume mark. ... his means that it would be very ha rd to control the force by which the dissolvent should be ejected step up of the pipette, thus the delivered solution may be slightly more than what is expected. Although there is a banal amount of force when it comes to delivering the solution out of the pipette, the deviation from the standard is brought about by individual differences as no two or three people can exactly deliver the solution out of the pipette using the same amount of force. Besides, this force is too little and is very hard to quantify and estimate physically. Another possible source of error or deviation from the absolute value of the solution is the possibility that the pipette is dirty or the solution is contaminated, thus there is a possibility that tiny droplets of the solution are left on the walls of the pipette resulting in the delivery of too little solution (Sources of Error in Pipetting). Moreover, dirt in the pipette, no outcome how little, may cause a slight obstruction in the flow of the outgo ing solution thus there is also a possibility that the pipette amount of solution is less than what is expected. Another possible source of error or deviation from the absolute or expected value is the possibility of a broken or chipped pipette, no matter how small the break is (Sources of Error in Pipetting). Such a break may cause a gap in the natural flow of the liquid out of the pipette, thus the outgoing solution is also less than the expected amount. Part B Conclusion The volume delivered by the pipette was calculated to be 9.99+/- 0.02 mL. The slight change of +/- 0.02 mL is due to a number of factors such as differences in time slip away during transfer of liquid, possible change in temperature, possible change in evaporation rate, lack of
Subscribe to:
Post Comments (Atom)
No comments:
Post a Comment